Miscellaneous - Other involving Aerospatiale SA365C-2, VH-HCF, 5 km west of Prospect, New South Wales, on 14 October 1990

199002013

Summary

Circumstances:

The helicopter was hovering at a height of 35 ft as part of a training exercise to provide a doctor and a paramedic with experience in winching procedures. The doctor, who was in the sling suspended on the winch cable, was raised to within 5 ft of the helicopter when there was an uncommanded firing of the explosive cable cutter. The doctor fell 30 ft and sustained serious injuries. Investigation revealed the uncommanded firing had resulted from a short circuit in the winch electrical system caused by a blown power resistor in the winch motor circuit. This allowed a substantial current flow in the cable cutter, sufficient to fire the squib. The current flow was not contained within the body of the hoist because of poor bonding between the winch motor and its mounting. The resistor failed due to inadequate heat dissipation at high current flow. The Civil Aviation Authority (CAA) subsequently issued a mandatory requirement to remove pyrotechnic cable cutting devices from helicopter hoists when used to raise or lower personnel. Additionally, both the CAA and the manufacturer have issued mandatory requirements to rectify the bonding problem pending a technical solution to preclude power resistor overheating.

Significant Factors:

The following factors were considered relevant to the development of the accident

1. Inadequate heat dissipation of the motor power resistor resulted in the failure of the resistor at high current load.

2. Inadequate bonding (high resistance) between the hoist, mount and airframe caused the current to flow through the squib (low resistance), resulting in uncommanded activation of the squib.

Recommendations:

1. That the CAA evaluate all hoist types for potentially similar problems.

2. That the CAA consider a modification of hoist circuit control to isolate the cable cutter squib by means of a close proximity relay to prevent stray currents from firing the squib.

3. That the CAA amend or re-issue Airworthiness Directive AD/SUPP/12 to activate squibs for all operations other than training exercises when personnel are to be winched.

4. That the CAA amend Civil Aviation Order 29.11 to include in the personnel briefing that a pyrotechnic cutting device is installed and will be used if required during an emergency.

Occurrence summary

Investigation number 199002013
Occurrence date 14/10/1990
Location 5 km west of Prospect
State New South Wales
Report release date 23/09/1991
Report status Final
Investigation type Occurrence Investigation
Investigation status Completed
Mode of transport Aviation
Aviation occurrence category Miscellaneous - Other
Occurrence class Accident
Highest injury level Serious

Aircraft details

Manufacturer Aerospatiale Industries
Model SA365
Registration VH-HCF
Serial number 5068
Sector Helicopter
Operation type Aerial Work
Departure point Westmead Hospital NSW
Destination Westmead Hospital NSW
Damage Nil