| Safety issue description |
The procedures for locomotive inspection and maintenance were not effective at identifying and addressing continuing fuel leakage problems on this type of fuel filter assembly. |
|---|---|
| Issue number | RO-2014-010-SI-01 |
| Issue owner | Pacific National and Downer EDI Rail |
| Transport function | Rail: Rolling stock |
| Date issue released | 31/10/2014 |
| Issue status justification |
PN/DEDI have increased the inspection requirements to address the mode of failure by the clevis. |
| Action type | Proactive action |
|---|---|
| Action number | RO-2014-010-NSA-002 |
| Organisation | Pacific National and Downer EDI Rail |
| Action date | 31/10/2014 |
| Action description |
As a result of this occurrence, Pacific National, in conjunction with Downer EDI Rail advised that the following safety actions have been implemented:
|
| ATSB response |
The Australian Transport Safety Bureau is satisfied that the actions taken by PN and DEDIR address this safety issue. |
| Action status | Closed |