| Safety issue description |
The maintenance of the opening/closing arrangements for Marigold’s engine room fire dampers, ventilators and other openings was inadequate. A number of these could not be closed, resulting in the inability to seal the engine room to contain and suppress the fire. |
|---|---|
| Issue number | MO-2014-008-SI-02 |
| Issue owner | Korea Leading Company of Ship Management (KLCSM) |
| Transport function | Marine: Shipboard operations |
| Date issue released | 20/04/2016 |
| Issue status justification |
Proactive safety action take |