Safety issue

Safety issue description

The safety information provided to passengers did not adequately explain that oxygen will flow to the masks without the reservoir bag inflating.

Issue number AO-2008-053-SI-02
Issue owner Qantas Airways
Transport function Aviation: Air transport
Date issue released 22/11/2010
Issue status justification

In-flight passenger briefings have been amended.

Safety action

Action type Proactive action
Action number AO-2008-053-NSA-056
Organisation Qantas Airways
Action date 22/11/2010
Action description The operator indicated that the standard pre-flight safety video / briefings provided to passengers have been modified to reinforce the message that users must pull down on the mask firmly to activate oxygen flow, and to include the comment 'Oxygen will flow without the bag inflating'.
ATSB response Accepted
Action status Closed

Safety action

Action type Safety advisory notice
Action number AO-2008-053-SAN-105
Organisation Operators of pressurised transport-category aircraft
Action date 22/11/2010
Action description

The Australian Transport Safety Bureau advises that operators of transport category aircraft fitted with pressurised gaseous oxygen systems should consider the safety implications of these safety issues, with a view to ensuring that passenger briefings provide sufficient detail and instruction as to the functionality of the system and the actions necessary to appropriately activate the flow of oxygen.

ATSB response

N/A

Action status Closed