Final report
Report release date: 31/10/2006
Executive summary
On 17 May 2005, a Boeing 717-200 aircraft, registered VH-VQI, was scheduled to operate a regular public transport flight from Hobart, Tas, to Sydney, NSW, departing at 0600 Eastern Standard Time, with 6 crew and 26 passengers. During the starting of the right engine at 0606, the aircraft dispatcher noticed sparks on the outer right side of the engine cowl and informed the pilot in command (PIC) to shut down the right engine as there was a fire. The sparks were due to a failure of the right engine air turbine starter during the engine start sequence. As the right engine was spooling down, the dispatcher noticed that the amount of sparks and smoke was still increasing and he told the PIC ‘we’ll have to get everyone off’. The PIC replied ‘Do you want me to do an evacuation?’ which the dispatcher confirmed. The PIC then immediately made a public address system (PA) announcement ‘This is your captain. Evacuate, evacuate, evacuate’. The investigation found that the flight crew were engaged in conversations not confined to the engine start process or other operational matters during both engine start sequences. The operator’s sterile flight deck policy for flight crew did not commence until after the engines were started. There was some misinterpretation of information between the aircraft dispatcher and PIC due to a lack of standard phraseology and no evacuation awareness education for aircraft dispatchers.
Twenty three seconds after the PIC made the evacuation PA announcement, he called for flaps 25. Eight seconds later, at the PIC’s direction, the copilot started to read the ‘Passenger Evacuation Checklist’ from the checklist card they had been using for earlier checks. The evacuation occurred while the morning was still in darkness. As a result of the PIC calling for the passengers to evacuate the aircraft before the Passenger Evacuation Checklist was initiated: the wing flaps were not set to the extended position while passengers were exiting the aircraft (as is necessary when using overwing exits); the emergency lights in the dark tail section of the aircraft were not illuminated during the evacuation; and the copilot was still completing the checklist with the PIC in the cockpit up to the time all passengers had evacuated and so could not direct the evacuation from the ground. As a further result, the cabin crew evacuated themselves from the aircraft without making any contact with the flight crew and the flight deck door remained closed and locked.
All three of the floor level exits were opened by the cabin crew. When the cabin manager (CM) opened forward Door Left 1 (L1) outwards, a queue of passengers was waiting behind her and the first passenger started to run out the door until the CM yelled ‘wait’ and grabbed the back of his clothing and pulled him back. Then she pushed the door open fully and the evacuation slide inflated. The investigation found that the operator’s door opening procedures called for flight attendants to guard the door while they were being opened for an emergency evacuation, but did not provide instructions for flight attendants to explain to passengers to wait as the slide was still inflating.
When the forward Door Right 1 (R1) flight attendant opened that door, the escape slide was pulled out of the door and fell to the ground still contained in its clear bag. The flight attendant then grabbed hold of the handle and repeated ‘blocked exit, move forward’. The investigation found that the door may have been incorrectly armed before the evacuation. The R1 flight attendant was unaware that this door’s girt bar had a fixed floor bracket rather than two spring latches. The operator’s procedures called for visual cross-checking of the door arming from the opposite side of the aircraft and did not include touch confirmation.
A number of ground personnel ran to the front of the aircraft and assisted the 21 adult passengers and one infant who exited through the L1 door and slide. These passengers were helped off the slide and were directed towards the terminal by the ground staff. After about three passengers were down the L1 slide, the aircraft’s tail cone was ejected. Four passengers exited by the Door 2 slide at the rear of the aircraft and ran into the middle of the apron. The overwing exits were not opened. The investigation found that none of the operator’s ground personnel present had been given any education about policy or procedures during an aircraft evacuation on the apron near the terminal.
As a result of the occurrence, a number of safety actions were taken by the aircraft operator and the Australian Transport Safety Bureau.
Occurrence summary
| Investigation number | 200502137 |
|---|---|
| Occurrence date | 17/05/2005 |
| Location | Hobart Aerodrome |
| State | Tasmania |
| Report release date | 31/10/2006 |
| Report status | Final |
| Investigation type | Occurrence Investigation |
| Investigation status | Completed |
| Mode of transport | Aviation |
| Aviation occurrence category | Fire |
| Occurrence class | Serious Incident |
| Highest injury level | Minor |
Aircraft details
| Manufacturer | The Boeing Company |
|---|---|
| Model | 717 |
| Registration | VH-VQI |
| Serial number | 55095 |
| Sector | Jet |
| Operation type | Air Transport High Capacity |
| Departure point | Hobart, Tasmania |
| Destination | Sydney, New South Wales |
| Damage | Minor |