Piper PA23-250, VH-MBU, Essendon VIC, 29 May 1986

198601420

Summary

The pilot was carrying out a pre-flight inspection of the aircraft in preparation for an Instrument Rating flight test. He had selected the flaps down, and began operating the hydraulic hand pump to extend the flaps. After a few pump cycles, the right maingear collapsed and the pilot then noted that the gear selector was in the up position. It was suspected that the anti-retraction valve, which is designed to prevent gear retraction on the ground, was unserviceable. However, no fault was discovered. Tests determined that the gear could be unlocked if the hand pump was operated rapidly, and the pilot advised that he had pumped briskly on this occasion. The check list provided by the aircraft operator did not alert pilots to confirm the position of the gear handle before using the hydraulic hand pump. It was not possible to establish why or by whom the gear selector had been placed in the up position.

Occurrence summary

Investigation number 198601420
Occurrence date 29/05/1986
Location Essendon
Report release date 06/02/1987
Report status Final
Investigation type Occurrence Investigation
Investigation status Completed
Mode of transport Aviation
Occurrence class Accident
Highest injury level None

Aircraft details

Manufacturer Piper Aircraft Corp
Model PA-23
Registration VH-MBU
Operation type Flying Training
Departure point Essendon VIC
Destination Essendon VIC
Damage Substantial