The pilot reported that the engine stopped suddenly at about 120 feet during initial climb. As there was insufficient altitude to return to the strip, an emergency landing was effected into a near-by paddock. Investigation determined that the flexible rubber induction ducting had detached and been sucked into the carburettor box blocking off the air supply to the carburettor.

Download Final Report
[ Download PDF: 21KB]
 
 
 
 
General details
Date: 13 April 1990 Investigation status: Completed 
Time: 841 Investigation type: Occurrence Investigation 
Location:Maitland  
State: New South Wales  
Release date: 10 May 1991 Occurrence category: Accident 
Report status: Final Highest injury level: None 
 
Aircraft details
Aircraft manufacturer: Victa Ltd 
Aircraft model: 115 
Aircraft registration: VH-KHP 
Serial number: 113 
Type of operation: Private 
Damage to aircraft: Substantial 
Departure point:Maitland NSW
Departure time:840
Destination:Wagga NSW
 
 
 